950SG Series Thermal Window Wall

Dual Strut Ultra-Thermal Barrier Silicone Sealed Glazing (SSG) System

Providing condensation resistance
even in extreme cold weather

900RW Series Thermal Window Wall

Dual Strut Ultra-Thermal Barrier Silicone Sealed Glazing (SSG) System

Providing condensation resistance even in extreme cold weather

900RW Series Thermal Window Wall

Dual Strut Ultra-Thermal Barrier Silicone Sealed Glazing (SSG) System

Providing condensation resistance even in extreme cold weather


Tubelite’s 950SG Series offers:

Tubelite’s 950SG Series offers solutions for between slab window wall applications. The 4- side SSG system has a 6″ or 7-3/4″ depth and is installed entirely from the building interior. A vertical silicone diverter replaces the need for an exterior applied seal.

Optional integrated slab edge covers can be extruded aluminum or brake metal to finish off the building’s exterior. Head, sill and jamb starters enable complete installation from the inside of the building. The 3” sightline head starter also provides +/- ¾” vertical interstory movement.

Labor Savings with Thermal Performance

The dual strut ultra-thermal barrier provides industry leading performance where more stringent energy codes apply.

A single piece anti-buckling clip simplifies installation with fewer parts and steps.

The 950SG Series Thermal Window Wall is available with Tubelite’s high recycled aluminum content, Ecoluminum, and environmentally friendly paint and anodized finishes from Linetec.

System Features:

  • Dual strut ultra-thermal barrier options help ensure compliance to project energy requirements. See U-Factor and CRF performance data below.
  • Three [3] sill options: 3-¼” std, 2-¼” low profile and SSG (no exposed metal).
  • Dual finish option available.
  • Two-piece vertical mullions allow continuous SSG glazed verticals.
  • Can be used with MaxBlock sun shades.
  • Head and sill starters, slab edge covers, pre-glazed frames.
  • Inside and Outside corner extrusion profiles.
  • The system is assembled and glazed prior to installation.
Performance Test Standards
Air Performance ASTM E 283
Water AAMA 501.1, ASTM E 331 and ASTM E 547
Structural ASTM E 330, ASTM E 501.4 and ASTM E 501.7
Thermal AAMA 1503 and NFRC 102
Thermal Break AAMA 505 and AAMA TIR-A8
Acoustical AAMA 1801 and ASTM E 1425
Thermal Cycling AAMA 501.5

Tubelite’s 950SG Series offers:

Tubelite’s 950SG Series offers solutions for between slab window wall applications. The 4- side SSG system has a 6″ depth and can be installed entirely from the building interior. A vertical silicone diverter replaces the need for an exterior applied seal.

Optional integrated slab edge covers can be extruded or brake metal to finish off the building’s exterior. The system design eliminates the need for an exterior seal at the sill starter. Head, sill and jamb starters enable complete installation from the inside of the building. The 3” sightline head starter also provides +/- ¾” vertical interstory movement.

Labor Savings with Thermal Performance

The dual strut ultra-thermal barrier provides industry leading performance where more stringent energy codes apply.

A single piece anti-buckling clip simplifies installation with fewer parts and steps.

The 950SG Series Thermal Window Wall is available with Tubelite’s high recycled aluminum content, Ecoluminum, and environmentally friendly paint and anodized finishes from Linetec.

System Features:

  • Dual strut ultra-thermal barrier options help ensure compliance to project energy requirements. See U-Factor and CRF performance data below.
  • Three [3] sill options: 3-¼” std, 2-¼” low profile and SSG (no exposed metal).
  • Dual finish option available.
  • Two-piece vertical mullions allow continuous SSG glazed verticals.
  • Can be used with MaxBlock sun shades.
  • Head and sill starters, slab edge covers, pre-glazed frames.
  • Inside and Outside corner extrusion profiles.
  • The system is assembled and glazed prior to installation.
Performance Test Standards
Air Performance ASTM E 283
Water AAMA 501.1, ASTM E 331 and ASTM E 547
Structural ASTM E 330, ASTM E 501.4 and ASTM E 501.7
Thermal AAMA 1503 and NFRC 102
Thermal Break AAMA 505 and AAMA TIR-A8
Acoustical AAMA 1801 and ASTM E 1425
Thermal Cycling AAMA 501.5
950SG Series Product Specifications
Application: Office, mixed use, healthcare, education, between slab system, interior and exterior glazing.
Description: 2-1/4″ x 6″ or 7-3/4″ overall depth exterior set, screw spline construction, dual thermal strut, field or shop glazed window wall.
Face Width: Overall Depths: Glass
Thickness:
Air Infiltration/
Exfiltration:
Static/Dynamic
Cyclic Water:
Structural
(L/175):
U-Factor:
(By Sill):
CRFf:
(By Sill):
Acoustic: Interstory Liveload: Product
Approval:
(non-impact)
2-1/4″

3″ w/starter

6″
&
7-3/4″
1”
&
1-1/16″
0.06 CFM/Ft.2 15 PSF 40 PSF – Design

60 PSF – Overload

Std – 0.34
Low – 0.35
SSG – 0.33
Std – 81
Low – 81
SSG – 82
1” IGU:
38 STC, 32 OITC
1-1/16” IGU:

41 STC, 30 OITC
+/- 3/4” FL 40971

** U-Factor per NFRC 100.

950SG Series Product Specifications
Application: Office, mixed use, healthcare, education, between slab system, interior and exterior glazing.
Description: 2-1/4″ x 6″ exterior set, screw spline construction, dual thermal strut, field or shop glazed window wall.
Face Width: 2-1/4″, 3″ w/starter
Overall Depths: 6″
Glass Thickness: 1” & 1-1/16″
Air Infiltration: 0.06 CFM/Ft.2@ 6.24 PSF
Static & Dynamic Water: 15 PSF
Structural (L/175): 40 PSF Design, 60 PSF Overload
U-Factor** By Sill: Std – 0.34, Low – 0.35, SSG – 0.33, NFRC 100
CRF (Frame): Std – 81, Low – 81, SSG – 82
Sound Transmission: 1” IGU, 31 STC, 28 OITC, 1 1/16” IGU, 36 STC, 31 OITC
Interstory Movement: +/- 3/4”
Product Approval:
(non-impact):
Coming Soon

** U-Factor per NFRC 100: COG = 0.24 with warm edge spacer, 1-3/4” x 4-1/2” non-thermal frame.

Guide Specification
Perimeter Sheet – DWG / PDF 6″ 7-3/4″
   |       |   
Design Manuals 6″ 7-3/4″
Installation Instructions 6″ 7-3/4″
BIM Models (16mb)
Sun Shade Installation Manual
Windload Charts (ASD format)
Mullion Female – Male
Mullion Male – Jamb Starter
Safety Data Sheets – SDS
Sample Warranty
Slab Edge Covers    |   
Air-Water-Structural
AAMA 1503
Thermal Test Report – (based on 6” system, contact engineering for 7-3/4” system data)
Acoustic