400T Thermal Curtainwall Cutaway

400T Thermal Curtainwall

Tubelite’s thermally broken curtainwall product has been designed to meet or exceed today’s stringent energy codes. The 400T Series Curtainwall has a 2-1/2″ face, with system depths from 6-1/4″ to 10-1/4″ and optional thermal pressure plates. The shear block system can be stick fabricated for field glazing.

Beauty and Performance

The expanded thermal break and thicker gasketing improves U-Factors and CRF over Tubelite’s current 400CW Series Curtainwall thermal barrier system when using the same size and type of insulated glass. Glass is positioned to the system exterior for enhanced resistance to rainwater. 11 anodized finishes and 19 standard paint colors are available on this framing system to complement any project with warranteed protection, as well as street appeal. The 400T also accepts Tubelite’s operable windows, Therml=Block® Doors, and Maxblock® Sunshades.

400T Series low-and mid-rise is recommended for use on medium- and low-rise applications. The 1/2″ bite securely grips insulated glass or panels of 1″ thickness. Infill thicknesses from 1/8″ to 1-5/16″ also can be accommodated. Verticals can be steel-reinforced for high performance against strong windloads. An improved horizontal member allows for expansion/contraction clearances to minimize splice requirements.

Thorough testing by an independent laboratory ensures the 400T is the highest quality curtainwall framing product the industry has to offer.

EXAMPLES >

DC Group
Minneapolis, MN

400T Thermal Curtainwall

Tubelite’s thermally broken curtainwall product has been designed to meet or exceed today’s stringent energy codes. The 400T Series Curtainwall has a 2-1/2″ face, with system depths from 6-1/4″ to 10-1/4″ and optional thermal pressure plates. The shear block system can be stick fabricated for field glazing.

Beauty and Performance

The expanded thermal break and thicker gasketing improves U-Factors and CRF over Tubelite’s current 400CW Series Curtainwall thermal barrier system when using the same size and type of insulated glass. Glass is positioned to the system exterior for enhanced resistance to rainwater. 11 anodized finishes and 19 standard paint colors are available on this framing system to complement any project with warranteed protection, as well as street appeal. The 400T also accepts Tubelite’s operable windows, Therml=Block® Doors, Maxblock® Sunshades and aLuminate® Light Shelves.

400T Series low-and mid-rise is recommended for use on medium- and low-rise applications. The 1/2″ bite securely grips insulated glass or panels of 1″ thickness. Infill thicknesses from 1/8″ to 1-5/16″ also can be accommodated. Verticals can be steel-reinforced for high performance against strong windloads. An improved horizontal member allows for expansion/contraction clearances to minimize splice requirements.

Thorough testing by an independent laboratory ensures the 400T is the highest quality curtainwall framing product the industry has to offer.

EXAMPLES >

DC Group
Minneapolis, MN

400T Series Product Specifications*
Application: Low and mid-rise commercial buildings including retail, office, healthcare, schools, etc.
Description: 2-1/2″ x (6-1/4″ to 10-1/4″) field glazed, shear block construction curtainwall.
Face Width: Overall Depths: Glass: Air Infiltration: Water Infiltration: Structural: U-Factor:** CRF: Acoustic:
2-1/2″ 6-1/4″ to
10-1/4″
1”
(1/8″ to
1-5/16″)
0.06 CFM / Ft.2
@ 6.24 PSF
15 PSF – Static
15 PSF – Dynamic
40 PSF Design
60 PSF Overload
U-Factor Table CRF-Value 32 STC
26 OITC
400T Series Product Specifications*
Application: Low and mid-rise commercial buildings including retail, office, healthcare, schools, etc.
Description: 2-1/2” x (6-1/4” to 10-1/4”) field glazed, shear block construction curtainwall.
Face Width: 2-1/2″
Overall Depths: 6-1/4″ to 10-1/4″
Glass: 1″ (1/8″ to 1-5/16″)
Air Infiltration: 0.06 CFM / Ft.2 @ 6.24 PSF
Water Infiltration: 15 PSF – Static; 15 PSF – Dynamic
Structural: 40 PSF Design; 60 PSF Overload
U-Factor:** U-Factor Table
CRF: CRF-Value
Acoustic: 32 STC; 26 OITC

** U-Factor per NFRC 100: COG = 0.24 with warm edge spacer, 1-3/4” x 4-1/2” non-thermal frame.

Guide Specification
Perimeter Sheet – DWG / PDF
Pressure Plate Aluminum Thermal
6-1/4” System Depth   |     |  
7-1/4” System Depth   |     |  
7-3/4” System Depth   |     |  
7-3/4” System Depth w/ Horiz. Exp.   |  
8-1/4” System Depth   |     |  
9-1/4” System Depth   |     |  
10-1/4” System Depth   |     |  
Optional Face Covers   |  
Optional Back Members   |  
BIM Models
Design Manual
Installation Instructions
Curtainwall Pressure Plate Fastener Torque Guide
Windload Charts (ASD format)
Safety Data Sheets – SDS
Sample Warranty
Pressure Plates    |   
Air-Water-Structural
CRF
Aluminum PP
Polyamide PP
Thermal PP
Acoustic