14000 I/O Series Storefront
The I/O means more design options!
Glass or panels can be positioned to the inboard (I) or outboard (O) side of the 4-1/2″ depth frame to achieve the look you require. Typical glass thickness is 1″, and can be installed from the outside or inside of the building. Special glazing pocket reducers allow the use of 1/4″ infill thicknesses, too.
Our redesigned T14000 I/O Series Storefront single cavity pour and debridge thermal barrier insulates exterior surfaces from the interior to minimize temperature transfer. This provides industry accepted performance for condensation resistance and energy performance. The system is based on #12 screw fasteners which greatly decreases rework in the field.
Using the same design, assembly, and accessories as the 14000 center glazed system allows combining inboard, outboard and center planes of glass in the same elevation with the same great performance.
14000 I/O Series Storefront
The I/O means more design options!
Glass or panels can be positioned to the inboard (I) or outboard (O) side of the 4-1/2″ depth frame to achieve the look you require. Typical glass thickness is 1″, and can be installed from the outside or inside of the building. Special glazing pocket reducers allow the use of 1/4″ infill thicknesses, too.
Our redesigned T14000 I/O Series Storefront single cavity pour and debridge thermal barrier insulates exterior surfaces from the interior to minimize temperature transfer. This provides industry accepted performance for condensation resistance and energy performance. The system is based on #12 screw fasteners which greatly decreases rework in the field.
Using the same design, assembly, and accessories as the 14000 center glazed system allows combining inboard, outboard and center planes of glass in the same elevation with the same great performance.
E14000 I/O Series Product Specifications | ||||||||
Application: Low-rise commercial buildings including retail, office, healthcare, schools, etc. Description: 2″ x 4-1/2″ multi-plane outside or inside flush glazed storefront. |
||||||||
Face Width: | Overall Depths: | Glass: | Air Infiltration: | Water Infiltration: | Structural: | Acoustic*: | ||
2″ | 4-1/2″ | 1″ std (1/8″ – 1-1/8″) |
0.06 CFM/Ft.2 @ 6.24 PSF |
12 PSF Inboard Plane 12 PSF Outboard Plane |
30 PSF Design 45 PSF Overload |
STC 31 OITC 25 |
*Based on 1″ IGU glass makeup of: 1/4″ ext., 1/2″ air space, 1/4″ interior
T14000 I/O Series Product Specifications | ||||||||
Application: Low-rise commercial buildings including retail, office, healthcare, schools, etc. Description: 2″ x 4-1/2″ multi-plane outside or inside flush glazed storefront. |
||||||||
Face Width: | Overall Depths: | Glass: | Air Infiltration: | Water Infiltration: | Structural: | U-Factor**: | CRF: | Acoustic: |
2″ | 4-1/2″ | 1″ std (1/8″ – 1-1/8″) |
0.06 CFM/Ft.2 @ 6.24 PSF |
12 PSF Inboard Plane 12 PSF Outboard Plane |
30 PSF Design 45 PSF Overload |
0.42 – Inboard Plane 0.34 – Outboard Plane 0.43 – SSG Outboard Plane Note: Full U-Factor Table Coming Soon |
52F 61G – Inboard Plane 67F 69G – Outboard Plane 64F 63G – SSG Outboard Plane |
STC 31 OITC 25 |
** U-Factor per NFRC 100.
E14000 I/O Series Product Specifications | |
Application | Low-rise commercial buildings including retail, office, healthcare, schools, etc. |
Description | 2″ x 4-1/2″ center set, outside or inside flush glazed storefront. |
Face Width | 2″ |
System Depth | 4-1/2″ |
Glass | 1” std (1/8″ – 1-1/8″) |
Air Infiltration | 0.06 CFM/Ft.2 @ 6.24 PSF |
Water Infiltration | 10 PSF Inside Plane , 12 PSF Outside Plane |
Structural | 30 PSF Design, 45 PSF Overload |
Acoustic | STC 31, OITC 25 |
*Based on 1″ IGU glass makeup of: 1/4″ ext., 1/2″ air space, 1/4″ interior
T14000 I/O Series Product Specifications | |
Application | Low-rise commercial buildings including retail, office, healthcare, schools, etc. |
Description | 2″ x 4-1/2″ center set, outside or inside flush glazed storefront. |
Face Width | 2″ |
System Depth | 4-1/2″ |
Glass | 1” std (1/8″ – 1-1/8″) |
Air Infiltration | 0.06 CFM/Ft.2 @ 6.24 PSF |
Water Infiltration | 10 PSF Inside Plane , 12 PSF Outside Plane |
Structural | 30 PSF Design, 45 PSF Overload |
U-Factor** | 0.42 – Inboard Plane 0.34 – Outboard Plane 0.43 – SSG Outboard Plane Note: Full U-Factor Table Coming Soon |
CRF*: | 52F 61G – Inboard Plane 67F 69G – Outboard Plane 64F 63G – SSG Outboard Plane |
Acoustic | STC 31, OITC 25 |
** U-Factor per NFRC 100.
EXAMPLES >
Arlington Falls
Columbus, OH
Boys and Girls Club
Austin, TX
UC Health Cancer Center
Ft. Collins, CO