ForceFront® Storm Monumental Stile 2″

Providing a high level of impact, air and water resistance.

ForceFront Storm Logo

ForceFront® Storm Monumental Stile 2″

Providing a high level of impact, air and water resistance.

ForceFront Storm Logo

ForceFront Monumental Wide Stile impact resistant entrance doors are rated for windzone 4 – large & small missile impact [ASTM E1886-05/1996-09] and passed the forced entry test [AAMA 1304-02]. These 6″ Wide Stile doors are glazed with 1-1/16″ thick laminated insulated glass and are wet glazed on the interior side. Transom glass in all door frames are wet glazed. Door frames are non thermal, and are available with options for heavy-wall extrusions and steel reinforcing where required. Thresholds are equipped with bulb weatherseal gaskets and are ADA accessible. Hinging hardware options include heavy duty mortised butts and continuous gear hinges. Locking types can be concealed vertical rod panics or deadlocks.

A complete evaluation performed by a Professional Engineer is required for each project.

ForceFront Storm Monumental Wide Stile Doors Testing

  • Designed for compliance with HVHZ Windzone 4, – Large Missile Impact, [ASTM E1886-05/E1996-09 TAS 201]
  • 100 PSF +/- cyclic loading for 3′0″ x 7′0″ single doors thru 6′0″ x 7′0″ pairs
  • Forced Entry Test [AAMA 1304-02]
  • Large Missile Impact Test – [ASTM E1886-05/1996-09 TAS 201]
  • Forcefront Storm E34000 Forcefront Impact Resistant Storefront also available

ForceFront Monumental Wide Stile impact resistant entrance doors are rated for windzone 4 – large & small missile impact [ASTM E1886-05/1996-09] and passed the forced entry test [AAMA 1304-02]. These 6″ Wide Stile doors are glazed with 1-1/16″ thick laminated insulated glass and are wet glazed on the interior side. Transom glass in all door frames are wet glazed. Door frames are non thermal, and are available with options for heavy-wall extrusions and steel reinforcing where required. Thresholds are equipped with bulb weatherseal gaskets and are ADA accessible. Hinging hardware options include heavy duty mortised butts and continuous gear hinges. Locking types can be concealed vertical rod panics or deadlocks.

A complete evaluation performed by a Professional Engineer is required for each project.

ForceFront Storm Monumental Wide Stile Doors Testing

  • Designed for compliance with HVHZ Windzone 4, – Large Missile Impact, [ASTM E1886-05/E1996-09 TAS 201]
  • 100 PSF +/- cyclic loading for 3′0″ x 7′0″ single doors thru 6′0″ x 7′0″ pairs
  • Forced Entry Test [AAMA 1304-02]
  • Large Missile Impact Test – [ASTM E1886-05/1996-09 TAS 201]
  • Forcefront Storm E34000 Forcefront Impact Resistant Storefront also available
ForceFront Storm Monumental Stile 2″
Application Stile Width: Frame Depth
or Max Size:
Test
Pressure:
Outside HVHZ
-Approved:
Impact
Approval:
Inside HVHZ
– Approved:

Single up to 3′0″ x 7′0″
Pairs up to 6′0″ x 7′0″

6″ Single Leaf: 48″ x 96″
Pair: 96″ x 96″
+/-100 PSF Yes Yes
FL14563.2
Yes
FL14563.1
Product Matrix: ForceFront Storm – Entrances
Application

Single up to 3′0″ x 7′0″

Pairs up to 6′0″ x 7′0″

Stile Width: 6″
Frame Depth or Max Size: Single Leaf:
48″ x 96″
Pair: 96″ x 96″
Test Pressure: +/-100 PSF
Outside HVHZ -Approved: Yes
Impact Approval: Yes FL14563.2
Inside HVHZ -Approved: Yes
FL14563.1
Guide Specifications
BIM Models
      MonDr Single wMuntin
      MonDr Pair wMuntin
      MonDr Pair
Safety Data Sheets
Tubelite Sample Warranty
Monumental Wide Stile Doors – HVHZ
Details
      Hurricane Series
Monumental Doors
      HVHZ Monumental Doors