ForceFront Storm Curtainwall (FFS-CW) Framing is a 2-1/2″ face pressure bar system for use on single and twin-span applications in impact building code areas. This captured or silicone-glazed system is designed for use with 1-5/16″ laminated glass. FFS-CW meets the requirements of HVHZ windzone 4 – large missile impact [ASTM E1886-05/1996-09 TAS 201].

ForceFront Medium Stile and Monumental Entrance Doors compliment the curtainwall providing a complete impact-resistant system that’s easy to fabricate and install. These doors meet the requirements of windzone 3 – large missile impact [ASTM E1886-05/1996-09] and passed the forced entry test [AAMA 1304-02].

FFS-CW is available with a thermally improved tongue area using an EPDM isolator between interior and exterior members. It can be ordered with Tubelite’s high recycled aluminum content of Ecoluminum®, and both the storefront and doors with the environmentally friendly anodizing and painting.

ForceFront Storm Curtainwall (FFS-CW) 2-1/2″ x 7-13/16″
Glass Makeup: 1-5/16″ Insulated Lami: 1/4″ (ext) – 1/2″ air space – 9/16″ lami (int) – options in table below
Approvals: Florida Product Approval including HVHZ and Texas Department of Insurance
Options: Single and twin span, captured, structural glazed horizontals and verticals, 90O corners,
wet and dry glazing, and ForceFront Storm Doors (under separate approval)
Hurricane Testing: Large Missile (D) and Small Missile (A) ASTM E1886-05 / 1996-09, TAS 201-94, and TAS 203-94
Air Infiltration: 0.06 cfm/ft2 @ 6.24 psf ASTM E283-04 and TAS 202-94
Water Resistance: 15.6 psf (static and dynamic) ASTM E331-00, TAS 202-94, and AAMA 501.1-05
U- Factor**: 0.40 (captured) 0.32 (SSG) NFRC 100, glazed wall configuration
CRF (frame): 68 AAMA 1503-09
Thermal Cycling: 0° F – 180°F AAMA 501.5-07
Structural: up to +90 / -90 psf ASTM E330-02 and TAS 202-94

** U-Factor per NFRC 100: COG = 0.24 with warm edge spacer, 1-3/4” x 4-1/2” non-thermal frame.

ForceFront-Storm Curtainwall (FFS-CW) Framing is a 2-1/2″ face pressure bar system for use on single and twin-span applications in impact building code areas. This captured or silicone-glazed system is designed for use with 1-5/16″ laminated glass. FFS-CW meets the requirements of HVHZ windzone 4 – large missile impact [ASTM E1886-05/1996-09 TAS 201].

Forcefront Medium Stile and Monumental Entrance Doors compliment the curtainwall providing a complete impact-resistant system that’s easy to fabricate and install. These doors meet the requirements of windzone 3 – large missile impact [ASTM E1886-05/1996-09] and passed the forced entry test [AAMA 1304-02].

FFS-CW is available with a thermally improved tongue area using an EPDM isolator between interior and exterior members. It can be ordered with Tubelite’s high recycled aluminum content of Ecoluminum®, and both the storefront and doors with the environmentally friendly anodizing and painting.

ForceFront Storm Curtainwall (FFS-CW) 2-1/2″ x 7-13/16″
Glass Makeup:
1-5/16″ Insulated Lami: 1/4″ (ext) – 1/2″ air space – 9/16″ lami (int) – options in table below
Approvals:
Florida Product Approval including HVHZ and Texas Department of Insurance
Options:
Single and twin span, captured, structural glazed horizontals and verticals, 90O corners,
wet and dry glazing, and ForceFront Storm Doors (under separate approval)
Hurricane Testing:
Large Missile (D) and Small Missile (A)
ASTM E1886-05 / 1996-09, TAS 201-94, and TAS 203-94
Air Infiltration:
0.06 cfm/ft2 @ 6.24 psf
ASTM E283-04 and TAS 202-94
Water Resistance:
15.6 psf (static and dynamic)
ASTM E331-00, TAS 202-94, and AAMA 501.1-05
U- Value**:
0.40 (captured) 0.32 (SSG)
NFRC 100, glazed wall configuration
CRF (frame):
68
AAMA 1503-09
Thermal Cycling:
0° F – 180°F
AAMA 501.5-07
Structural:
up to +90 / -90 psf
ASTM E330-02 and TAS 202-94

** U-Value per NFRC 100

ForceFront Storm Curtainwall Product Specifications
Glass Size (max) Frame Height
(max)
Design
Pressure
(psf)
Missile Type Interlayer
Makeups Tested*
Texas Department
of Insurance
(TDI)
Florida Product
Approval (FPA)
Florida Building
Code HVHZ
Single Span Captured
(dry glazed)
60″ x 95 1/4″ 149″ + / – 70 Large (D) 1/4″ T – .090 Sentry Glas – 1/4″ HS CWFS-41

FL17035.3

Yes
Single Span Captured
(wet glazed)
60″ x 119 3/4″ 148 1/4″ + / – 90 Large (D) 1/4″ T – .090 Sentry Glas – 1/4″ HS CWFS-41

FL17035.3

Yes
Twin Span Captured
(wet glazed)
60″ x 120 3/4″ 30′- 7 1/4″ + / – 70 Large (D) 1/4″ T – .090 Sentry Glas – 1/4″ HS Coming Soon

FL17035.3

Yes
1/4″ T – .075 Saflex CP – 1/4″ HS
+78 / -71 Small (A) 1/4″ T – .060 Butacite PVB – 1/4″ HS CWFS-41
Single Span SSG 48″ x 120″ 148 1/4″ + / – 60 Large (D) 1/4″ T – .090 Sentry Glas – 1/4″ HS CWFS-41

FL17035.1

Yes
1/4″ T – .075 Saflex CP – 1/4″ HS
Small (A); 1/4″ T – .060 Butacite PVB – 1/4″ HS
Twin Span SSG 48″ x 120″ 30′- 6 1/4″ + / – 60 Large (D) 1/4″ T – .090 Sentry Glas – 1/4″ HS CWFS-41

FL17035.1

Yes
1/4″ T – .075 Saflex CP – 1/4″ HS
Small (A) 1/4″ T – .060 Butacite PVB – 1/4″ HS
ForceFront Storm Curtainwall Product Specifications
Single Span Captured (dry glazed)
Glass Size (max) 60″ x 95 1/4″
Frame Height (max) 149″
Design Pressure (psf) + / – 70
Missile Type Large (D)
Interlayer Makeups Tested* 1/4″ T – .090 Sentry Glas – 1/4″ HS
Texas Department of Insurance (TDI) CWFS-41
Florida Product Approval (FPA) FL17035.3
Florida Building Code HVHZ Yes
Single Span Captured (wet glazed)
Glass Size (max) 60″ x 119 3/4″
Frame Height (max) 148 1/4″
Design Pressure (psf) + / – 90
Missile Type Large (D)
Interlayer Makeups Tested* 1/4″ T – .090 Sentry Glas – 1/4″ HS
Texas Department of Insurance (TDI) CWFS-41
Florida Product Approval (FPA) FL17035.3
Florida Building Code HVHZ Yes
Twin Span Captured (wet glazed)
Glass Size (max) 60″ x 120 3/4″
Frame Height (max) 30′- 7 1/4″
Design Pressure (psf) + / – 70
Missile Type Large (D)
Interlayer Makeups Tested* 1/4″ T – .090 Sentry Glas – 1/4″ HS
1/4″ T – .075 Saflex CP – 1/4″ HS
Texas Department of Insurance (TDI) Coming Soon
Design Pressure (psf) +78 / -71
Missile Type Small (A)
Interlayer Makeups Tested* 1/4″ T – .060 Butacite PVB – 1/4″ HS
Texas Department of Insurance (TDI) CWFS-41
Florida Product Approval (FPA) FL17035.3
Florida Building Code HVHZ Yes
Single Span SSG
Glass Size (max) 48″ x 120″
Frame Height (max) 148 1/4″
Design Pressure (psf) + / – 60
Missile Type Large (D)
Interlayer Makeups Tested* 1/4″ T – .090 Sentry Glas – 1/4″ HS
1/4″ T – .075 Saflex CP – 1/4″ HS
Missile Type Small (A)
Interlayer Makeups Tested* 1/4″ T – .060 Butacite PVB – 1/4″ HS
Texas Department of Insurance (TDI) CWFS-41
Florida Product Approval (FPA) FL17035.3
Florida Building Code HVHZ Yes
Twin Span SSG
Glass Size (max) 48″ x 120″
Frame Height (max) 30′- 6 1/4″
Design Pressure (psf) + / – 60
Missile Type Large (D)
Interlayer Makeups Tested* 1/4″ T – .090 Sentry Glas – 1/4″ HS
1/4″ T – .075 Saflex CP – 1/4″ HS
Missile Type Small (A)
Interlayer Makeups Tested* 1/4″ T – .060 Butacite PVB – 1/4″ HS
Texas Department of Insurance (TDI) CWFS-41
Florida Product Approval (FPA) FL17035.3
Florida Building Code HVHZ Yes
Guide Specification
BIM Models
CW1 Contact Engineering
CW2 Contact Engineering
Safety Data Sheets – SDS
Sample Warranty
Single & Twin Span Curtainwall
Perimeter Sheet – DWG / PDF Contact Engineering
Design Manual Contact Engineering
Installation Instructions Contact Engineering
Evaluation Reports
Impact Rated
400CW – Captured
Impact Rated
Mock-up Drawing
Non-Impact Rated
400CW – Captured
Non-Impact Rated
Mock-up Drawing
SSG Twin Span Curtainwall
Perimeter Sheet – DWG / PDF Contact Engineering
Design Manual Contact Engineering
Installation Instructions
Evaluation Reports
Impact Rated
400CW – SSG
Impact Rated
Mock-up Drawing
Non-Impact Rated
400CW – SSG – Captured
Non-Impact Rated
Mock-up Drawing
System Type Filename Test Report No’s Glass Types
Captured Impact Resistant Evaluation
CW400-Cap-Impact-EvalDrawing
CW400-Impact-Captured-8-27-15
B3864.01-450-18,
B3864.03-450-18, B3864.04-450-18, and
B3864.05-450-18
Glazing Type 1 – 0.090” Kuraray (Dupont) Sentry Glas

  • [Table A-Twin Span-Wet Glazed] Design Pressure +/-70 PSF, Large Missile, <48″ glass width x <118.75”

DLO

  • [Table C-Single Span-Wet Glazed] DP +/-90 PSF, Large Missile, <60″ gw x <148.25″ frame height
  • [Table D-Single Span-Dry Glazed] DP +/-70 PSF, Large Missile, <60″gw x <149”fh

Glazing Type 2 – 0.090” Eastman Saflex (VS02)

  • [Table A-Twin Span-Wet Glazed] DP +/-70 PSF, Large Missile, <48″ glass width x <118.75” DLO

Glazing Type 3 – 0.090” Kuraray (Dupont) Butacite PVB

  • [Table B-Single Span-Wet Glazed] DP +/-65 PSF, Small Missile, <48″gw x <99.75”fh

Glazing Type 4 – 0.060” Kuraray (Dupont) Butacite PVB

  • [Table A-Twin Span-Wet Glazed] DP +78/-71 PSF, Small Missile, <60″gw x <118.75″ DLO
SSG Impact Resistant Evaluation
FL17035_R2_AE_CW400_-SSG-Impact-EvalDrawing
FL17035_R2_II_FPA-400-SSG-IMP
B3864.04-450-18 Glazing Type 1 – 0.090” Dupont Sentry Glas
Glazing Type 2 – 0.075” Eastman Chemical Saflex CP
Glazing Type 3 – 0.060” Dupont Butacite PVBSingle Span Max. 112” Frame Height, Max. 107” DLO Height

  • Design Pressure – +/-90 PSF, Glass Width  up to 30″
  • DP – +/-75.8 PSF, Glass Width up to 36″
  • DP – +/-65.2 PSF, Glass Width up to 42″
  • DP – +/-57.1 PSF, Glass Width up to 48″

Single Span Max. 148.25” Frame Height, Max. 118.5” DLO Height

  • DP – +72/-80 PSF, Glass Width  up to 32″
  • DP – +72/-78 PSF, Glass Width  up to 36″
  • DP – +/-68.5 PSF, Glass Width  up to 42″
  • DP – +/-60 PSF, Glass Width  up to 48″

Twin Span Max. 144” between anchor points, Max. 118.5” DLO Heights

  • DP – +/-63.3 PSF, Glass Width up to 45″
  • DP- +/-60 PSF, Glass Width up to 48
System Type Captured Impact Resistant
Filename: Evaluation
CW400-Cap-Impact-EvalDrawing
CW400-Impact-Captured-8-27-15
Test Report No’s: B3864.01-450-18,
B3864.03-450-18, B3864.04-450-18, and
B3864.05-450-18
Glass Types: Glazing Type 1 – 0.090” Kuraray (Dupont) Sentry Glas

  • [Table A-Twin Span-Wet Glazed] Design Pressure +/-70 PSF, Large Missile, <48″ glass width x <118.75”

DLO

  • [Table C-Single Span-Wet Glazed] DP +/-90 PSF, Large Missile, <60″ gw x <148.25″ frame height
  • [Table D-Single Span-Dry Glazed] DP +/-70 PSF, Large Missile, <60″gw x <149”fh

Glazing Type 2 – 0.090” Eastman Saflex (VS02)

  • [Table A-Twin Span-Wet Glazed] DP +/-70 PSF, Large Missile, <48″ glass width x <118.75” DLO

Glazing Type 3 – 0.090” Kuraray (Dupont) Butacite PVB

  • [Table B-Single Span-Wet Glazed] DP +/-65 PSF, Small Missile, <48″gw x <99.75”fh

Glazing Type 4 – 0.060” Kuraray (Dupont) Butacite PVB

  • [Table A-Twin Span-Wet Glazed] DP +78/-71 PSF, Small Missile, <60″gw x <118.75″ DLO
System Type SSG Impact Resistant
Filename: Evaluation
FL17035_R2_AE_CW400_-SSG-Impact-EvalDrawing
FL17035_R2_II_FPA-400-SSG-IMP
Test Report No’s: B3864.04-450-18
Glass Types: Glazing Type 1 – 0.090” Dupont Sentry Glas
Glazing Type 2 – 0.075” Eastman Chemical Saflex CP
Glazing Type 3 – 0.060” Dupont Butacite PVBSingle Span Max. 112” Frame Height, Max. 107” DLO Height

  • Design Pressure – +/-90 PSF, Glass Width  up to 30″
  • DP – +/-75.8 PSF, Glass Width up to 36″
  • DP – +/-65.2 PSF, Glass Width up to 42″
  • DP – +/-57.1 PSF, Glass Width up to 48″

Single Span Max. 148.25” Frame Height, Max. 118.5” DLO Height

  • DP – +72/-80 PSF, Glass Width  up to 32″
  • DP – +72/-78 PSF, Glass Width  up to 36″
  • DP – +/-68.5 PSF, Glass Width  up to 42″
  • DP – +/-60 PSF, Glass Width  up to 48″

Twin Span Max. 144” between anchor points, Max. 118.5” DLO Heights

  • DP – +/-63.3 PSF, Glass Width up to 45″
  • DP- +/-60 PSF, Glass Width up to 48