36000 ForceFront Storm Framing Extrusion

ForceFront® Blast E/T34000 Storefront

Providing a complete impact resistant system that’s easy to fabricate and install.

ForceFront Blast Logo

ForceFront® Blast E/T34000 Storefront

Providing a complete impact resistant system that’s easy to fabricate and install.

ForceFront Blast Logo

ForceFront® Blast E/T34000 Storefront

Providing a complete impact resistant system that’s easy to fabricate and install.

ForceFront Blast Logo

Tubelite’s 34000 Series Framing is a 2-1/2″ x 5″ flush glazed storefront system for use on low-rise single-span applications for resistance to bomb blast. This screwspline framing is designed to be glazed with 1-5/16″ laminated glass positioned in the center of the frame. 34000 meets the requirements of ASTM, GSA ISC and DoD requirements. ForceFront Monumental Wide Stile Entrance Doors complete the 34000 storefront system providing a complete system that’s easy to fabricate and install.

  • Blast Resistance Criteria
    • Analyzed in accordance with UFC 4-010-01
    • 121 Ft standoff – Charge weight I
    • 50 Ft standoff – Charge weight II
    • Each project must be analyzed separately for compliance based on its unique factors

ForceFront Monumental Entrance Doors

  • +/- 50PSF cyclic loading for 4′0″ x 8′0″ single doors thru 8′0″ x 8′0″ pairs
  • Forced Entry Test [AAMA 1304-02]

FORCEFRONT® BLAST PRODUCT LINE

ForceFront Blast E/T34000 Storefront

Tubelite 34000 Series Framing is a 2-1/2″ x 5″ flush glazed storefront system for use on low-rise single-span applications for resistance to bomb blast. This screwspline framing is designed to be glazed with 1-5/16″ laminated glass positioned in the center of the frame. 34000 meets the requirements of ASTM, GSA ISC and DoD requirements. ForceFront Monumental Wide Stile Entrance Doors complete the 34000 storefront system providing a complete system that’s easy to fabricate and install.

  • Blast Resistance Criteria
    • Analyzed in accordance with UFC 4-010-01
    • 121 Ft standoff – Charge weight I
    • 50 Ft standoff – Charge weight II
    • Each project must be analyzed separately for compliance based on its unique factors

ForceFront Monumental Entrance Doors

  • +/- 50PSF cyclic loading for 4′0″ x 8′0″ single doors thru 8′0″ x 8′0″ pairs
  • Forced Entry Test [AAMA 1304-02]
E/T34000 ForceFront Blast Storefront Specifications
Application: Low and mid-rise commercial buildings including retail, office, healthcare, schools, etc,.
Description: 2-1/2″ x 5″ field glazed, screw spline construction blast resistant storefront.
Face Width: Overall Depths: Glass: Air Infiltration: Water Infiltration: Structural: T34000 U-Factor:** T34000 CRF: Acoustic: HVHZ Approved:
2-1/2″ 5″ 1 3/16”
to
1-5/16″
0.06 CFM / Ft.2
@ 6.24 PSF
15 PSF – Static
15 PSF – Dynamic
70 PSF Design
105 PSF Overload
U-Factor Table CRF-Value 36 STC
32 OITC
No
E/T34000 ForceFront Blast Storefront Specifications
Application: Low and mid-rise commercial buildings including retail, office, healthcare, schools, etc.
Description: 2-1/2″ x 5″ field glazed, screw spline construction blast resistant storefront.
Face Width: 2-1/2″
Overall Depths: 5″
Glass: 1 3/16” to 1-5/16″
Air Infiltration:  0.06 CFM / Ft.2 @ 6.24 PSF
Water Infiltration: 15 PSF – Static, 15 PSF – Dynamic
Structural: 70 PSF Design, 105 PSF Overload
T34000 U-Factor:** U-Factor Table
T34000 CRF: CRF Value
36 STC, 32 OITC
HVHZ – Approved NO

** U-Factor per NFRC 100: COG = 0.24 with warm edge spacer, 1-3/4” x 4-1/2” non-thermal frame.

Guide Specification
Perimeter Sheet – DWG / PDF
T34000 (Thermal)    |   
E34000 (Non Thermal)    |   
BIM Models
Design Manual
PE Guidance
E/T34000
Installation Instructions
Safety Data Sheets – SDS
Air-Water Structural
CRF
Acoustic