FORCEFRONT STORM – MEDIUM STILE ENTRANCE
Tubelite’s ForceFront Medium Stile impact resistant entrance doors are rated for windzone 4 – large & small missile impact [ASTM E1886-05/1996-09] and passed the forced entry test [AAMA 1304-02]. These 4″ Medium Stile doors are glazed with 1-1/16″ thick laminated insulated glass and are wet glazed on the interior side. Transom glass in all door frames are wet glazed. Door frames are non-thermal, and are available with options for heavy-wall extrusions and steel reinforcing where required. Thresholds are equipped with bulb weatherseal gaskets and are ADA accessible. Hinging hardware options include heavy duty morised butts and continuous gear hinges. Locking types can be concealed vertical rod panics or deadlocks.
ForceFront Storm Medium Stile Doors Testing
- Designed for compliance with HVHZ Windzone 2, – Large Missile Impact, [ASTM E1886-05/E1996-09 TAS 201]
- 50PSF +/- cyclic loading for 3′0″ x 7′0″ single doors thru 6′0″ x 7′0″ pairs
- Forced Entry Test [AAMA 1304-02]
- Large Missile Impact Test – [ASTM E1886-05/1996-09 TAS 201]
- Forcefront Storm E34000 Forcefront Impact Resistant Doors also available
FORCEFRONT STORM – MEDIUM STILE ENTRANCE
Tubelite ForceFront Medium Stile impact resistant entrance doors are rated for windzone 4 – large & small missile impact [ASTM E1886-05/1996-09] and passed the forced entry test [AAMA 1304-02]. These 4″ Medium Stile doors are glazed with 1-1/16″ thick laminated insulated glass and are wet glazed on the interior side. Transom glass in all door frames are wet glazed. Door frames are non-thermal, and are available with options for heavy-wall extrusions and steel reinforcing where required. Thresholds are equipped with bulb weatherseal gaskets and are ADA accessible. Hinging hardware options include heavy duty morised butts and continuous gear hinges. Locking types can be concealed vertical rod panics or deadlocks.
ForceFront Storm Medium Stile Doors Testing
- Designed for compliance with HVHZ Windzone 2, – Large Missile Impact, [ASTM E1886-05/E1996-09 TAS 201]
- 50PSF +/- cyclic loading for 3′0″ x 7′0″ single doors thru 6′0″ x 7′0″ pairs
- Forced Entry Test [AAMA 1304-02]
- Large Missile Impact Test – [ASTM E1886-05/1996-09 TAS 201]
- Forcefront Storm E34000 Forcefront Impact Resistant Doors also available
ForceFront Storm Medium Stile | ||||||
Application | Stile Width: | Frame Depth or Max Size: |
Test Pressure: |
Outside HVHZ -Approved: |
Impact Approval: |
Inside HVHZ – Approved: |
Single up to 3′0″ x 7′0″ |
4″ | Single Leaf: 35-13/16″ x 83-5/16″ | +/-50 PSF | Yes FL16891 |
Yes FL17191[Forced Entry] |
No |
ForceFront Storm Medium Stile | |
Application |
Single up to 3′0″ x 7′0″ |
Stile Width: | 4″ |
Frame Depth or Max Size: | Single Leaf: 35-13/16″ x 83-5/16″ |
Test Pressure: | +/-50 PSF |
Outside HVHZ -Approved: | Yes – FL16891 |
Impact Approval: | Yes – FL17191 [Forced Entry] |
Inside HVHZ -Approved: | No |